Home

News

Contact

Seminars

About Us

 

 Home

 Swath Bathymetry

 Side Scan Sonar

 Sub Bottom Profiler

 Software

 Acoustic Tracking

 Documentation

 Image Gallery

 Full Product Listing

 

 

 

© GeoAcoustics 2008

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GeoPulse Pipeliner Specification

Transmitter - Model 5430P

Output: 5 kW with 0.75% duty cycle, continuously adjustable. 2 to 12 kHz, and switchable to 14kHz. Short circuit proof. Impedance matched.
Pulse Cycles: 1, 2, 4, 8, 16, or 32 cycles of the frequency selected.  The transmitted output pulse will be phase coherent within 22.5°.
Key: External: 2 to 12 V pulse, either + or – leading edge triggered. Maximum width 50ms to eliminate double triggering. Transformer isolated.
  Internal: Set by internal potentiometer, 1 to 10pps, uncalibrated.
Output to Receiver or digital sonar processing system: Transformer isolated. Frequency response flat between approximately 1 kHz and 20 kHz. Two modes of operation:
A: Flat gain –0 dB gain
B: Short range TVG -20 dB (10:1) of attenuation during transmit pulse and a –20 dB to 0dB ramp within 15ms after end of transmit signal.
Power: 115/230 VAC +/- 10%, 47 to 63 Hz, 220 W maximum.
Auxiliary Power: IEC connector, unfused, 6A maximum.
Environmental: Operational: -5 to 50°C, Storage: –15 to 85°C
Dimensions: 45.7cm (L) x 43cm (W) x 13cm (H), 18kg

Receiver Model 5210A

Amplifier: Differential common mode rejection: 100dB at 60Hz. Sensitivity 30µV RMS in, produces 1V RMS out at 90dB total gain with TVG.
Signal to Noise: 20dB at 100dB gain 1kHz centre frequency and 1kHz bandwidth.
Coarse Gain: 40dB maximum.
Fine Gain: 0-30dB in 3dB increments.
Filter: Low pass and high pass, active type, maximally flat, 24dB/octave minimum roll-off, 0 gain, 0.02kHz to 15kHz adjustable in ½ octave increments. Knobs interlock to prevent overlap.
TVG: Dynamic range: 30dB.
Rate: approximately flat to 30dB in 14 ms.
Manual delay: vernier adjust from 1 to 14ms with multiplier of x 1, x 10, x 100 and internal select of x 1000.
AGC: Attack adjustable from 330µs to 330ms.
Decay: adjustable from 330µs to 330ms.
Range: 20dB.
Power: 115/230VAC ±10% (internal switch selectable), 47 to 63Hz, 45W maximum.
Environmental: Operational: -5 to 50°C, Storage: –15 to 85°C
Dimensions: 45.7cm (L) x 43cm (W) x 17.8cm (H), 12kg.

Models 132P & 136P (fitted with Model T135 and T14 transducers for buried pipeline dedection)

Beam pattern designed to maximise pipeline parabolic signature.

Frequency Along Track Across Track
3.5kHz 120° 55°
5.0kHz 100° 55°
7.0kHz 80° 35°
14.0kH° 80° 15°

 

Dimensions: 132P: 70cm (L) x 52cm (W) x 46cm (H), 120kg.
  Mounting Staff: One section 183cm, two sections 360cm.
  136P: 156cm (L) x 46cm (W) x 46cm (H), 125kg.

Specifications subject to change without notice.

Download Data Sheets & Downloads